top of page

Борьба с асбестом и усиление; Удаление

ACM

(Asbestos Containing Material) – Commercial asbestos product containing more than 1%
asbestos. ACM must be disposed as hazardous waste. Note: Federal OSHA and Cal-OSHA
control materials containing any amount of asbestos.

ACBM

(Asbestos Containing Building Material) – AHERA/ASHARA term for material containing
more than 1% asbestos in or on interior structural members or other structural components.
Includes covered walkways, porticos and exterior HVAC TSI.

ACCM

(Asbestos Containing Construction Material) – California term for a manufactured
construction material containing greater than .1% (one tenth of one percent) asbestos.


PACM

(Presumed Asbestos Containing Material) OSHA considers all TSI and surfacing materials

installed prior to1980 to be ACM unless proven otherwise.

Friable

Asbestos Containing Material that can be crumbled pulverized or reduced to powder by hand

pressure when dry.

NOA

Naturally Occurring Asbestos. CARB defines as having >.25% by point counting.


Acm

CARB term for naturally occurring asbestos >.25% by point counting


DACM

Designated Asbestos Containing Material: Floor tile installed before 1981

Борьба с асбестом и усиление; Удаление

TSI

(Thermal System Insulation) - “Thermal system insulation (TSI)” means ACM applied to
pipes, fittings, boilers, breeching, tanks, ducts or other structural components to prevent heat
loss or gain. “Thermal system insulation ACM” is thermal system insulation which contains
more than 1% asbestos.

SURFACING (usually mixed on site at time of application)

“Surfacing material” means material that is sprayed, troweled-on or otherwise applied to
surfaces (such as acoustical plaster on ceilings and fireproofing materials on structural
members, or other materials on surfaces for acoustical, fireproofing, and other purposes).
“Surfacing ACM” means surfacing material which contains more than 1% asbestos. NOTE:
OSHA/Cal-OSHA do not classify skim coat, taping mud, floor tile mastic, stucco, leveling
compound, and hard wall plasters or wall texturing as surfacing.

MISC.

All other ACM, including classify taping mud, floor tile mastic, stucco, leveling compound,

and hard wall plasters or wall texturing as surfacing.

Борьба с асбестом и усиление; Удаление

Category I

Cat I Non-friable Asbestos Containing Material(ACM) refers to asbestos containing packing,
gaskets, resilient floor covering, Galbestos, and asphalt roofing products containing more than
1% asbestos.

Category II

Cat II Non-friable Asbestos-Containing Material (ACM) is any material that is not Cat I that

contains greater than 1% asbestos.

RACM

“Regulated Asbestos-Containing Material.” – Friable manufactured asbestos material (ACM)
or a Category I non-friable ACM that has become friable OR a Category I non-friable ACM
that will be or has been subjected to sanding, grinding, cutting or abrading OR Category II
non-friable ACM that has a high probability of becoming or has become crumbled,
pulverized, or reduced to powder by the forces expected to act on the material in the course of
demolition or renovation operations. RACM should be removed prior to renovation or
demolition.

ЛИЦЕНЗИИ И amp; КВАЛИФИКАЦИЯ:
 

• Лицензия Б; CSLB № 1048237 (штат Калифорния)
• Сертификат DOSH, регистрационный номер штата Калифорния № 795.
• Департамент производственных отношений (DIR) Рег. #1000063421
• Лицензия ASB (строительство, связанное с асбестом)
• Лицензия C22 (удаление асбеста)
• Лицензия C21 (снос и переезд зданий)
• Лицензия C33 (живопись)
• Ведущая RRP-фирма, сертифицированная EPA, № NAT-66681-1.
• Зарегистрированный перевозчик опасных отходов DOT, DTSC, CHP
• Сотрудники AHERA (Asb.) и CDPH (ведущие специалисты), сертифицированные государством.

Office Hours:

Mon - Fri     9:30 am - 6:00 pm

Saturday   10:00 am - 3:00 pm

Job-Site Hours:

Mon - Fri     8:00 am - 4:00 pm

Address:   1080 Wentworth St

                  Mountain View, CA 94043

  Phone:    (650) 347-9100

  E-mail:    info@reliance-const.com

  • Instagram
  • Facebook
  • YouTube

All information provided on this website, including any legal or health advice, is not to be taken as your final answer. This information may not be the most current and is intended to help guide you on where to start and where to find the necessary details. It is your responsibility to verify that the information is correct and up to date. Reliance Construction disclaims any liability for actions taken based on the information provided on this site. We do not provide professional legal or health advice.

bottom of page